DKG-605DSD-050
ALARM EXTENSION UNITS
* 8 channel alarm annunciator, alarm
extension and automatic shutdown
functions
* 8 configurable input channels
* Generator phase voltage input
* Underspeed/Overspeed protection
* 2 relay outputs for warning and
shutdown conditions
* Individual semiconductor outputs for
each input channel
* Programmable using DKG-605 Hand
Terminal
* Dimensions: 72x72x70mm (WxHxD)
* Earthquake shutdown unit based on
microprocessor controlled acceleration
sensors
* Direct connection to electromechanical
solenoid valves
* Internal 12Vdc battery and battery charger
* Seismic properties conformal to ANSI
Z.21-70 (1981) and ASCE 25-97
standards
* Non-seismic accelerations filtered
* Capable of performing self-test
* Maintenance free
DSD-060
* Based on silicon micromachined
acceleration sensors, this unit detects
seismic acceleration and generates
control signals to shutdown any critical
devices
* Seismic properties conformal to ANSI
Z.21-70 (1981) and ASCE 25-97
standards
* Microprocessor controlled,
* Non-seismic accelerations filtered
* Capable of performing self-test
* Maintenance free
* Separate outputs for standard and high
sensitivity
* Operates on 10 to 30 volts DC
* Direct interface to gensets, elevators and
alarm systems
* Overload and short circuit protected
relay outputs
* Resin molded design
SMPS 123/124/125/1210/242/243/245/2410
* These are fixed output voltage, current limited
lead acid battery chargers specially designed
for permanent connection to genset starter
batteries. They maintain the batteries fully
charged, without overcharging or gassing.
* The chargers are designed in switchmode
technology. Their rugged design allows
surviving in harsh electromagnetic
environments found in automotive industry.
* The low weight of the unit makes it ideal for
use in highly vibrating generator control
panels. The small dimensions allow compact
panel design.
* Thanks to their high efficiency, the self-
heating of the chargers is kept in minimum
levels allowing operation in warm
environments.
* 100 KHz switchmode architecture,
* Float charging system,
* Constant voltage output,
* Current limited,
* Rugged design for industrial
environments,
* Rectifier fail output
* Boost charge input
* Short circuit protection
* Overload protection
* High temperature protection
* Plug-in connection system
* Operating voltage range: 170-270 VAC
* Operating frequency range: 45-65 Hz
* Operating temp range: -20 to +70 °C
volts
amps
SMPS-123 SMPS-125 SMPS-1210 SMPS-243 SMPS-245 SMPS-2410
13.7
3
13.7
5
13.7
10
27.4
3
27.4
5
27.4
10
SMPS-124
DIN RAIL
13.7
4
SMPS-242
DIN RAIL
27.4
2